If you get this error that device is not supported by running the default command
Device: ATA WDC WD800JD-60LS Version: 07.0
Serial number: WD-WMAM9F764913
Device type: disk
Local Time is: Tue May 15 13:12:49 2007 CDT
Device does not support SMART
Request Sense failed, [Input/output error]
Error Counter logging not supported
Error Events logging not supported
[GLTSD (Global Logging Target Save Disable) set. Enable Save with ‘-S on’]
Device does not support Self Test logging
Solution: add “-d ata” switch
=== START OF INFORMATION SECTION ===
Device Model: WDC WD800JD-60LSA0
Serial Number: WD-WMAM9F764913
Firmware Version: 07.01D07
User Capacity: 80,026,361,856 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue May 15 13:19:16 2007 CDT
SMART support is: Available – device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (2460) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 33) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always – 0
3 Spin_Up_Time 0x0003 175 172 021 Pre-fail Always – 2225
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always – 17
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always – 0
7 Seek_Error_Rate 0x000f 200 200 051 Pre-fail Always – 0
9 Power_On_Hours 0x0032 090 089 000 Old_age Always – 7761
10 Spin_Retry_Count 0x0013 100 253 051 Pre-fail Always – 0
11 Calibration_Retry_Count 0x0012 100 253 051 Old_age Always – 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always – 17
190 Unknown_Attribute 0x0022 062 055 045 Old_age Always – 38
194 Temperature_Celsius 0x0022 105 098 000 Old_age Always – 38
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always – 0
197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always – 0
198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline – 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always – 0
200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline – 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Aborted by host 50% 1 –
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Leave a Reply